成人影院激情av在线,天天中文字幕av天天爽,久久国语对白,亚洲另类国产欧美一区二区,北岛玲精品一区二区三区,欧美手机在线视频,免费无码又爽又刺激高潮的视频 ,亚洲精品久久区二区三区蜜桃臀
技術文章您現在的位置:首頁 > 技術文章 > 美國*RD試劑盒說明書(ELISA)

美國*RD試劑盒說明書(ELISA)

更新時間:2014-12-12   點擊次數:3382次

美國*RD試劑盒說明書(ELISA)

REAGENTS PROVIDED AND RECONSTTTUTION

REAGENTS(Store at 2-8℃)

1×96 WELLS

0.5×96 WELLS

RECONSTTTUTION

96/48-wells microtiter plates

1

0.5

Ready-to-use

Plastiv cover

2

1

Ready-to-use

Standard: 800ng/ml

1Vials  (0.6ml)

0.5Vials  (0.3ml)

See reagents preparation on page 3

Blank control

1Vials  (1.0ml)

1Vials   (0.5ml)

Ready-to-use

Standard Diluent

1Vials  (5ml)

1Vials   (2.5ml)

Ready-to-use

Biotinylated anti-Co IV

1Vials  (6ml)

1Vials   (3.0ml)

Ready-to-use

Streptavidin-HRP

1Vials  (10ml)

1Vials   (5.0ml)

Ready-to-use

Washing Buffer

1Vials  (20ml)

1Vials   (10ml)

50× concentrate

Substrate  A

1Vials  (6.0ml)

1Vials   (3.0ml)

Ready-to-use

Substrate  B

1Vials (6.0ml)

1Vials   (3.0ml)

Ready-to-use

Stopping Solution

1Vials  (6.0ml)

1Vials   (3.0ml)

Ready-to-use

Sample Diluent

1Vials  (12ml)

1Vials   (6.0ml)

Ready-to-use

MATERIAL REQUIRED BUT NOT PROVIDED

  • Distilled water
  • Pipettes:10ul、50ul、100ul、200ul、1000ul。
  • Vortex mixer and magnetic stirrer.

SAFETY

  • For research use only
  • Avoid any skin contact with H2SO4 and TMB. In case of contact, wash thoroughly water.
  • Do not eat, drink, smoke or apply cosmetics where kit reagents are used.
  • Do not pipette by mouth.

PROCEDURAL NOTES/LAB.QUALITY CONTROL

  • When not in use, kit components should be stored refrigerated or frozen as indicated on vials or bottles. All reagents should be warmed to room temperature before use. Lyophilized standards should be discarded after use.
  • Once the desired number of strips has been removed, immediay reseal the bag to protect the remaining strips from edterioration.
  • Cover or cap all reagents when not in use.
  • Do not mis or interchange reagents between different lots.
  • Do not use reagents beyond the expiration date of the kit .
  • Use a clean disposable plastic pipette tip for each reagent, standard, or specimen addition in order to avoid cross-contamination, for the dispensing of H2SO4 and substrate solution, avoid pipettes with metal parts.
  • Use a clean plastic container to prepare the washing solution.
  • Thoroughly mix the reagents and samples before use by agitation or swirling.
  • All residual washing liquid must be drained from the wells by efficient aspiration or by decantation followed by tapping the plate forcefully on absorbent paper. Never insert absorbent paper directly into the wells.
  • The TMB solution is light sensitive. Avoid prolonged exposure to light, also, avoid contact of the TMB solution with metal to prevent colour development. Warning TMB is toxic avoid direct contact with hands. Dispose off properly. If a dark blue colour develops within a few minutes after preparation, this indicates that the TMB solution has been contaminated and must be discarede. Read absorbances within 1 hour after completion of the assay.
  • When pipetting reagents, maintain a consistent order of addition from well-to-well. This will ensure equal incubation times for all wells.
  • Respect incubation times described in the assay procedure.

SPECIMEN COLLECTION\ PROCESSING AND STORAGE

  • Serum---Avoid any inintentional stimulation of the cells by the procedure. Use pyrogen\endotoxin free collecting tubes. Serum should be removed rapidly and carefully from the red cells after clothing. For that, after clothing, centrifuge at approximay 1000×g for 10 min and remove serum.
  • Plasma---EDTA\ citrate and heparin plasma can be assayed. Spin samples at 1000×g for 30 min remove particulates. Harvest plasma.
  • Cell culture supernatants---Remove particulates and aggregates by spinning at approximay 1000×g for 10 min.
  • Storage---If not analyzed shortly after collection, samples should be aliquoted(250-500ul) to avoid freeze-thaw cycles and stored frozen at -70℃. Avoid multiple freeze-thaw cycles of frozen specimens. When possible, avoid use of badly hemolyzed or lipemic sera. If large amounts of particles are present, this should be removed prior to assay by centrifugation or filtration.
  • Recommendation---Do not thaw by heating at 37℃ or 56℃. Thaw at room temperature and make sure that sample is compley thawed and homogenous before assaying.

PREPARATION OF REAGENTS

  • Standards: Standard have to be reconstituled with the volume of standard buffer diluent indicated on the vial. This reconstitution produces a stock solution of 800ng/ml Co IV. Allow standard to stand for 5
  • minutes with gentle swirling prior to making dilutions. Serial dilutions of standard must be made before each assys and cannot be stored.

800 ng/ml

(6  Standard)

Original density 50ul。

400 ng/ml

(5  Standard)

100ul  6 Standard  +100ul diludent

200 ng/ml

(4  Standard)

100ul  5 Standard  +100ul diludent

100 ng/ml

(3  Standard)

100ul  4 Standard  +100ul diludent

50 ng/ml

(2  Standard)

100ul  3 Standard  +100ul diludent

25 ng/ml

(1  Standard)

100ul  2 Standard  +100ul diludent

0 ng/ml

Blank Control

50ul。


  • Washing buffer 50×concentrate:  Dilute 50 times in distilled water.

ASSAY METHOD

  • Before use, mix all reagents thoroughly without making foam.
  • Determine the number of microwell strips required to test the desired number of samples,plus appropriate number of wells needed for running blanks standards. Each sample, standard and blank should be assayed in duplicate. Remove sufficient microwell strips from the pouch.
  • Add 50ul of standard diluent to standard wells B1,B2,  C1,C2,  D1,D2,  E1, E2,  F1,F2. Reconstitute standard vial with the appropriate volume as described in the chapter reagents preparation. Preparation. Pipet 100ul of standard into wells A1 and A2 (see plate scheme below). Transfer 50ul from A1 and A2 to B1 and B2 wells. Mix the contents by repeated aspirations and ejections. Take care not to scratch the inner surface of microwells. Repat this procedure from the wells B1,B2 to wells C1,C2 and from wells C1,C2 to D1,D2 and so on creating two parallel rows of Co IV standard dilutions ranging,Add 50ul of standard diluent to the bland wells.
  • Dilute samples 1:1 distribing 50ul of sample into 50ul of dilluent ,Add 50ul of diluted sample to wells..
  • Add 50ul of diluted biotinylated anti-Co IV to all wells.
  • Cover with a plate vover and incubate for 1 hour at 37℃.
  • Remove the cover and wash the plate as follows: ⑴ aspirate the liquid from each well, ⑵ dispensse 0.3ml of washing solution into each well. ⑶ Aspirate again the contet of each well after 0.5 minute. ⑷ Repeat steps ⑵ and ⑶ three times.
  • Distribute 80ul of streptavidin-HRP solution to all wells, including blank wells.
  • Cover and incubate 30 min at 37℃.
  • Remove the cover and empty wells, Wash microwell strips according to step, Proceed immediay to the next step.
  • Add 50ul Substrate A and Substrate B to each well。Incubate for 10 min at 37℃。
  • The enzyme-substrate reaction is stopped by quickly pipetting 50ul of H2SO4. stop reagent into each well, including the blank wells, to compley and uniformly inactivate the enzyme. Results must be red immediay after the addition of H2SO4.
  • Read absorbance of each well on a spectrophotometer using 450nm as the primary wavelength and optionally 620nm (610nm to 650nm is acceptable ) as the reference wavelength.

SUGGESTED PLATE SCHEME

 

Standard

concentrations(ng/ml)

 

A

800

800

sample

sample

sample

sample

sample

sample

sample

sample

sample

sample

B

400

400

sample

sample

sample

sample

sample

sample

sample

sample

sample

sample

C

200

200

sample

sample

sample

sample

sample

sample

sample

sample

sample

sample

D

100

100

sample

sample

sample

sample

sample

sample

sample

sample

sample

sample

E

50

50

sample

sample

sample

sample

sample

sample

sample

sample

sample

sample

F

25

25

sample

sample

sample

sample

sample

sample

sample

sample

sample

sample

G

0

0

sample

sample

sample

sample

sample

sample

sample

sample

sample

sample

H

sample

sample

sample

sample

sample

sample

sample

sample

sample

sample

sample

sample

LIMITATIONS OF THE PROCEDURE

Do not extrapolate the standard curve beyond the max  standard curve point. The dose-response is non-linear in this region and good accruacy is difficult to obtain.

CALCULATION OF RESULTS

The minimum detectable concentration in this assay is estimated to be 1.0ng/ml 

了解更多ELISA試劑盒說明書,歡迎您致電給我公司業務員索取,上海恒遠為您提供中、英文兩種語言詳細說明書。2015年RD試劑盒新品即將上市,敬請關注:




主站蜘蛛池模板: 少妇激情作爱视频| 无码国产精品成人| 欧美尺码专线欧洲b1b1| 在线人成视频播放午夜福利| 麻豆精产国品| 婷婷国产天堂久久综合亚洲| 2021少妇久久久久久久久久| 国产精品亚洲а∨天堂123| 国产亚洲精品美女久久久m| 国产在线观看免费人成视频| 精品一区二区三区影院在线午夜| 中文字幕亚洲日韩无线码| 男人的天堂免费一区二区视频| 亚洲裸男自慰gv网站| 成人片黄网站色大片免费观看cn| 亚洲精品入口一区二区乱| 亚洲中文av一区二区三区| 男男19禁啪啪无遮挡免费| 亚洲国产高清在线观看视频| 国产美女在线精品免费观看网址| 色久悠悠婷婷综合在线亚洲| 综合无码精品人妻一区二区三区| 美乳丰满人妻无码视频| 日本一区二区三区免费播放| 天天做天天欢摸夜夜摸狠狠摸| 欧产日产国产精品| 色翁荡息又大又硬又粗又视频软件 | 天天躁夜夜躁狠狠久久成人网| 一区二区三区乱码在线 | 中文| 亚洲精品自产拍在线观看动漫| 青青草国产精品一区二区| 午夜好爽好舒服免费视频| 日本工口里番无遮█彩色| 亚洲中文字幕国产综合| 国产精品成熟老女人视频| 亚洲人成网站在线播放无码| 久久r999热精品国产首页| 综合伊人久久在| 欧美国产精品日韩在线| 国产97超碰人人做人人爱| 国产精品视频色尤物yw|